Authentic batch verified.

Independently tested by CertikLabs. This page is a permanent, tamper-evident record.

Verified by Certik

Status

Authentic

Product

BPC-157

Lot / Batch

NW-24-A1207

Tested

Apr 28, 2026

Status

Authentic

Purity (HPLC)

98.74%

Mass (LC-MS)

1235.42 Da

Concentration

9.87 mg/vial

Sample

ProductBPC-157
VendorNorthwind Bio
Lot / BatchNW-24-A1207
Sample IDCL-1825-3C90-A8DD
ReceivedApr 24, 2026
TestedApr 28, 2026
ReleasedApr 30, 2026

Results summary

The submitted material matches the expected identity of BPC-157 with high purity and confirmed mass. Concentration is within ±2% of declared label. The batch passes all acceptance criteria and is released as Authentic.

Identity

Pass

Purity ≥ 95%

Pass

Concentration ±5%

Pass

HPLC Chromatogram

Reverse-phase, 214 nm

BPC-157 · 6.41 min

Main peak RT

6.41 min

Area %

98.74

Impurities

1.26%

LC-MS Spectrum

Positive ion mode

[M+H]⁺ 1235.42

Expected MW

1235.43 Da

Observed

1235.42 Da

Δ

0.01 Da

Methods

  • SOP-HPLC-014Purity, RP-HPLC/UV
  • SOP-LCMS-009Identity, ESI-MS
  • SOP-CONC-003Concentration, ref. std.

Glossary

Key terms, in plain language

A quick reference for the lab and cryptographic terms used on this page.

COA (Certificate of Analysis)
A signed document issued by a testing lab that lists what a specific batch was tested for and the results. CertikLabs publishes a tamper-evident, digitally signed COA for every verified batch.
Batch / Lot
A single production run of a product. Every vial in the same batch shares the same raw materials and process, so test results for one batch only apply to that batch — not to the next one.
SHA-256
A one-way cryptographic fingerprint. We hash each report with SHA-256 and publish the fingerprint on a public blockchain, so anyone can later confirm the report has not been altered.
HPLC (High-Performance Liquid Chromatography)
The lab method used to measure purity. The sample is separated into its individual components and the main peak's area is reported as a percentage — for peptides, ≥95% is the standard acceptance threshold.
LC-MS (Liquid Chromatography – Mass Spectrometry)
The lab method used to confirm identity. After separation, each component's exact molecular mass is measured and compared to the expected mass for the declared molecule.
On-chain anchor
The transaction on a public blockchain that records the SHA-256 fingerprint of a verification report. It proves when the result was sealed and that it has not been changed since.